Magnet Wire Termination: Serrated P-in with a Controlled Crimp
Magnet wire termination is often treated as a question of finding one connector for one wire size. SM Contact is looking at it as a strategy instead: start from the serrated P-in, add a controlled crimp, and adapt the combination to the wire. The approach is most valuable for ultra-fine wire of 0.08 mm, but it can work with larger wire as well.
The starting point
The P-in has sharp serrations along the pin body. They break through the enamel and contact the copper, so the wire does not need to be stripped. We have already tested it successfully on 0.22 mm magnet wire.
In the standard P-in process the compression cannot be controlled, and the serrations are 0.1 mm deep. With wire that has enough material to spare this is fine. With ultra-fine wire such as 0.08 mm the serrations are deeper than the wire diameter and could cut it.
A tin bath is not an easy alternative either. The insulation has to be removed, and handling fragile wire is tricky.
The strategy: separate the two jobs
In the standard P-in the serrations break the enamel and press on the wire at the same time. The new approach splits these jobs. The serrations only penetrate the enamel, and a separate crimp sets the contact force.
- Insert the P-in in the coil. The serrated zone is 0.1 mm deep, and its length can be chosen.
- Wrap the magnet wire around the pin.
- Close a splice crimp over it. A piece of stainless-steel (INOX) ribbon is crimped around the wire.
Why it works
Controlled compression. In a ribbon crimp we can control the compression very precisely. It can be set for each wire diameter and kept below the level at which the wire would be cut.
Several contacts, not one. The crimp creates several enamel penetrations, which means several robust electrical connections in parallel.
Stainless steel. In our experience INOX ribbon performs consistently better than copper alloy under thermal shock. One known reason is that copper alloy contacts slowly lose contact force at temperature through stress relaxation.
Easy to test
A first test needs only a pin, a few turns of wire and a piece of ribbon. The joint can be checked by contact resistance, pull-out force, a cross-section and a thermal shock test. For wire of 0.25 mm and above, IEC 60352-2 on crimped connections can serve as a reference. For finer wire the test plan is agreed case by case.
Talk to our engineers
Whether your wire is 0.08 mm or larger, contact the SM Contact team to plan a test with your own wire.